[Skip to main content]
Buderus logo

Buderus commercial and domestic boilers

[G 215 95kW]

Dimensions

Parameter Value
Number of sections 7
Length, LK 1040mm
Width 600mm
Width for access 460mm
Height 1111mm
Height max incl controls 1126mm
Transportation, Boiler section Width 460/Height 820/Depth 150mm
Transportation, Boiler block Width 460/Height 820/Depth LKmm
Net weight 362kg
Combustion chamber, LF 908mm
Combustion chamber, Ø 337mm
Burner door, Depth 95mm
Burner door, Ø DB 130mm
Burner door, Ø Hole circle 170mm
Adjusted feet, FL 815mm

Technical Parameters

Parameter Value
Output 95kW
Max working pressure 4bar
Max flow temperature 120°C
Rated heat input 76kW - 103.2kW
Water content 97l
Pressure at flue outlet 0Pa
Flue gas resistance 0.35mbar - 0.71mbar
Gas content 117.7l
CE certification, product ID no. CE 00 85 AS 0368
Nominal heat output 71kW - 95kW
Flue gas temperature 160°C - 198°C
Type approval no. Z-FDK-MUC-00-318-302-24
Efficiency (NCV) 95%

Return to G 215

 
Intelligent Heating SolutionsBosch Thermotechnology Ltd.